睿安

4+2 Line System

The 4+2 line system has the features of powerful function, fast communication speed, good compatibility, strong system expansion, safety and reliability, simple operation, easy installation and easy maintenance. Meet the needs of users for high-end functions, the need for personalization, and the need for a friendly human-computer interface. Use digital technology to create a comfortable, convenient, safe and efficient home life, bringing users a smart and humane life experience.


System Features

  • Guest call function: Call the household or administrator through the digital door machine at the door of the unit, enter the building after confirmation once, and open the unit electronic control door after confirmation by the household, which is safe and reliable;

  • Household call function: The resident calls the management center through the "paging" button of the videophone and realizes two-way conversation. Realize the unified management of households in the district;

  • Residents\' help function: When an emergency occurs in the household, press the "emergency call" button on the indoor unit for about 2 seconds (anti-touch protection function) or press the external "emergency call" button, and the help signal horse is uploaded to the management center. The administrator switchboard immediately cooperates with the housing number showing the accident, so that the residents receive timely support. In any case, press the extension emergency alarm button to give priority to the management center;

  • Inductive unlocking function: the household can open the unit door by sensing the head through the door machine of the unit through the induction card issued by the administrator;

  • System expansion function: applicable to all kinds of multi-layer, high-rise, visual and invisible mixing, to meet different needs;

  • Emergency power backup function: The system provides a backup power interface to ensure that the system can maintain normal use for a certain period of time under normal power supply conditions, and the communication is smooth and unobstructed;

  • Communication secret function: The system adopts the communication industry standard to ensure channel security and confidentiality;

  • Alarm function: When the indoor gas detector is installed in the household, the smoke detector detects harmful gas and fire, the fire Sydney number will be transmitted to the management center through the visual indoor extension; when the infrared, door magnet and window magnets trigger the alarm It will report directly to the management switchboard; the administrator switchboard will immediately cooperate with the housing number showing the accident, so that the residents can receive timely support. In any case, the alarm can give priority to the management center;

  • Property management function: The administrator switchboard set up in the residential property management office can automatically record 15 records, with the management software, so that the administrator can stay at home, complete the visitors and administrators, administrators and residents, visitors and residents. The call, and the opening of the administrator and the household, make the property management more perfect and improve the overall management efficiency of the community.




System Advantage

  • The product has strong performance and strong expandability; the function menu is rich, which enhances user's stickiness;
  • There are few intermediate devices, and the system quotation list is really light;
  • Hidden costs such as labor and maintenance are greatly reduced:

    a. The construction is simpler and the technical requirements for personnel are not high;
    b. The system is simple to install and debug, and the labor and time are greatly reduced;
    c. Less equipment, fewer points of failure, easier maintenance at a later stage, and the property can do the job.




System Architecture Diagram

Serial Number Product Device Description Configuration Standard
1 Management center machine Capacity: 9999 door machine 1 unit in a community
2 Wall machine Can communicate with all extensions in the community 99 units in a community
3 Outdoor Station Capacity: 9999 door machine 99 units
4 Networked controller Connecting floor platforms, door machines and campus networking One unit
5 Networking partitioner Cell segment management, a total of 8 roads More than 8 plus one
6 18V power supply Power the door machine / wall machine / network controller / indoor unit 1 set per 14 indoor units
7 Floor platform Connect indoor unit, household isolation There are 4, 6, and 8 roads.
Note: The alarm detector needs to be powered separately.
Engineering Installation

Wiring:Use a device-specific network cable. This system is a weak current system. It should be routed independently when wiring. Do not route with strong electric lines. When crossing with strong electric lines, it must be separated by more than 30CM distance, or add shielding isolation measures. When wiring the system, the socket connection is the same color connection. For details, please refer to the wiring diagram. Do not cut the grounding shield (ground) line in the connection. If the construction needs to be cut, please reconnect after the construction is completed. . The bottom wire of the floor must be grounded and connected to the networked iron wire. All joints must be welded to ensure good contact and heat-shrinkable sleeve protection. Be sure to check the plug when plugging in the plug. The length of the electric lock wiring should be less than 30 meters and the wire diameter should be no less than 0.5MM.

Door host:The door machine can't be installed on the movable door, and it should avoid direct sunlight, rain and snow, and can not see the water seep into the machine. Do not touch the transparent part with your hands and sharps, or use your hands to remove dirt or dust, once contaminated. Wash in time, but do not use organic solvents. The visual door machine camera window should avoid direct sunlight.

Power box:The power box is installed on the indoor wall closer to the main engine of the door and is fixed at a height of 150CM above the ground. It has good ventilation, but it is not particularly humid, high pressure and high temperature. The mains supply of this system should be supplied independently, and should not be used together with other systems.

Extension:Install and fix the hanging iron of the indoor unit according to the regulations, and then hang the indoor unit firmly. The installation position should be away from the strong radiation equipment such as TV, video recorder and computer. There is high voltage and danger in the indoor unit. Please do not open the protective cover yourself to avoid electric shock. Avoid damage to the indoor unit caused by strong vibration, collision, knocking, and falling, resulting in damage to internal precision components and casing.